What did you do?

Used Parameter.Value node after Element.Parameters node on a Element Type

What did you expect to see?

A list of parameter values

What did you see instead?

A list of parameter values - which was provided, just with a warning

Stacktrace/logs

Node Name: Parameter.Value
Package: Revit.Elements.Parameter.Query
Dynamo Version: 2.18.1.5096
Host: Dynamo Revit
Messages: Parameter.get_Value operation failed.
Parameter Autodesk.Revit.DB.Parameter has no storage type.
State: Warning

Details

The node still works with a warning - I guess it's just handing the edge case of a parameter with no storage type

Suspected code location

image
element_params_2

@emru-y
Copy link

emru-y commented May 7, 2024

Thank you for the feedback!
I guess for such cases where the node is throwing an error but still working maybe the representation of the warning color can be different than the nodes which is not working at all. @Amoursol