12V current monitoring sign reversed #66

Open
ldoolitt opened this issue Dec 8, 2020 · 0 comments
Open

12V current monitoring sign reversed #66

ldoolitt opened this issue Dec 8, 2020 · 0 comments

Comments

@ldoolitt
Copy link
Collaborator

ldoolitt commented Dec 8, 2020

U43, the INA219 monitoring the main +12V input voltage and current, has its IN+ and IN- pins reversed.
Current drawn by the board results in negative current readings.
It looks like the INA219 doesn't care, but humans and software might consider this unexpected or wrong.